Digital Junction Box LCT-2

(No reviews yet) Write a Review
$506.25
SKU:
LCT-2
Weight:
5.00 LBS
Capacity 3:
0
Connectivity2:
0
Weight:
5
Brand Logo:
https://cdn11.bigcommerce.com/s-jak2xff2ir/product_images/uploaded_images/transcell-logo-.png

Overview minus plus

The LCT-2 is a digital weight transmitter, combined with an intelligent junction box, for high-speed, individual monitoring of up to four individual load cells. The unit is able to measure and transmit filtered weight data to a programmable logic controller (PLC) or other compatible host device, via MODBUS® protocol or EthernNet/IP protocol.

A calibration-free feature provides for scaling of the LCT-2 to the load cell mV/V calibration data. This eliminates the need for conventional calibration methods utilizing test weights and/or material substitution.

Designed for in-plant applications, several unique capabilities help guard against costly downtime and the resultant product waste. These include real-time scale system diagnostics, capable of immediate fault detection. Based on high-speed analogto- digital conversion technology, the device can minimize the effects of long, analog homerun cable installations.

The sampling rate is adjustable from 4.7 Hz to 4800 Hz, with a resolution of 24 bits. Dead load cell emulation provides a workaround until a detected fault can be corrected, making the LCT-2 ideal for mission-critical systems requiring single or multiple scales with multiple cells.

The Transcell LCT-2 is designed to be highly flexible, adaptable to virtually any plant environment. Up to 20 industrial network protocols are supported. MODBUS® RTU and MODBUS® ASCII are standard. MODBUS® TCP/IP and EtherNet/IP™ are also available (with additional hardware). Other interface options include PROFIBUS, CAN open, and DeviceNet™.



  • Load Cell Excitation: +3.3 VDC
  • Load Cell Current: Drives up to four 350 Ω Load Cells
  • Analog Signal Input Range: +/- 3.125 mV/V max
  • Analog Sensitivity: 0.3 μV/grad, minimum 0.6 μV/grad, recommended
  • Serial Port: Half Duplex RS-485 Format
  • Power Requirements: 24 VDC, 0.5 A
  • Dimensions: 9.0” x 7.1” x 2.1”(228 mm x 181 mm x 53 mm)
  • A/D Conversion Rate: 4.7 Hz to 4800 Hz (adjustable)
  • A/D Resolution: 24 bits
  • No. of ADC channels: Four
  • Remote Functions: Zero, Start/Stop Stream Data, Demand Data, ADC counts
  • Operating Temperature: -14°F to 104°F (-10°C to 40°C)

Contact our Scales Specialist minus plus

Do you have a question about this Scale or do you want to order over email/phone? Please contact us at 866-643-3444 or write to us at contact@scales.net One of our Scale specialists will help you answer your questions and will help you complete the order. We thank you for shopping with Scales.net

Specifications minus plus

SKU:
LCT-2
Weight:
5.00 LBS
Capacity 3:
0
Connectivity2:
0
Weight:
5

Reviews minus plus

(No reviews yet) Write a Review
why sho-with-us

The LCT-2 is a digital weight transmitter, combined with an intelligent junction box, for high-speed, individual monitoring of up to four individual load cells. The unit is able to measure and transmit filtered weight data to a programmable logic controller (PLC) or other compatible host device, via MODBUS® protocol or EthernNet/IP protocol.

A calibration-free feature provides for scaling of the LCT-2 to the load cell mV/V calibration data. This eliminates the need for conventional calibration methods utilizing test weights and/or material substitution.

Designed for in-plant applications, several unique capabilities help guard against costly downtime and the resultant product waste. These include real-time scale system diagnostics, capable of immediate fault detection. Based on high-speed analogto- digital conversion technology, the device can minimize the effects of long, analog homerun cable installations.

The sampling rate is adjustable from 4.7 Hz to 4800 Hz, with a resolution of 24 bits. Dead load cell emulation provides a workaround until a detected fault can be corrected, making the LCT-2 ideal for mission-critical systems requiring single or multiple scales with multiple cells.

The Transcell LCT-2 is designed to be highly flexible, adaptable to virtually any plant environment. Up to 20 industrial network protocols are supported. MODBUS® RTU and MODBUS® ASCII are standard. MODBUS® TCP/IP and EtherNet/IP™ are also available (with additional hardware). Other interface options include PROFIBUS, CAN open, and DeviceNet™.



  • Load Cell Excitation: +3.3 VDC
  • Load Cell Current: Drives up to four 350 Ω Load Cells
  • Analog Signal Input Range: +/- 3.125 mV/V max
  • Analog Sensitivity: 0.3 μV/grad, minimum 0.6 μV/grad, recommended
  • Serial Port: Half Duplex RS-485 Format
  • Power Requirements: 24 VDC, 0.5 A
  • Dimensions: 9.0” x 7.1” x 2.1”(228 mm x 181 mm x 53 mm)
  • A/D Conversion Rate: 4.7 Hz to 4800 Hz (adjustable)
  • A/D Resolution: 24 bits
  • No. of ADC channels: Four
  • Remote Functions: Zero, Start/Stop Stream Data, Demand Data, ADC counts
  • Operating Temperature: -14°F to 104°F (-10°C to 40°C)